Model |
Noise level db(A) (*2) |
Pump speed | Final pressure (50 Hz) | Final pressure (50 Hz) |
Motor power kW |
Voltage V |
Weight kg |
Leak tightness Pa • m3/s |
Water vapor capacity g/Tag |
Air flushing L/min |
Inlet connection NW |
Outlet connection NW |
Cooling system |
Ambient temperature °C |
|||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
§ | m3/h | Single-phase | Three-phase | Single-phase | Three-phase | ||||||||||||
ISP-50 | 48 | 50 | 3.7 | 20 | 2.0 *10-1 | 0.1 | AC 100 V ; AC 200 V ; AC 230 V | - | 12 | - | 3 (with air flushing) | 4 | 25 | 16 | Air-cooled | 5~40 | |
ISP-90 | 52 (57 with air flushing) | 90 | 5.4 | 5 | 5.0 x 10-2 | 0.15 | 100, 115, 200, 230 (with temperature protection) | 14 | 5 (with air flushing) | 9 | |||||||
ISP-250C | 58 (66 with air flushing) | 250 | 15.0 | 1.6 | 1.6 x 10-2 | 0.4 | 200,208,230,380,450,460 | 25 | 23 | 25 (with air flushing) | 10 | 25 | 16 | Air-cooled | 5~40 | ||
ISP-500C | 60 (68 with air flushing) | 500 | 30.0 | 1 | 1.0x10-2 | 0.6 | 100, 115, 200, 230 (with temperature protection) | 44 | 38 | 40 | 25 | ||||||
ISP-1000E | 67 (74 with air flushing) | 1000 | 60.0 | 1.0 x 10-2 | 1.4 | - | 200,208,230,380,450,460 | - | 68 | 25 (with air flushing) | 40 | 40 | Air-cooled | 10~40 |
Model |
Noise level db(A) (*2) |
Pump speed | Final pressure (50 Hz) | Final pressure (50 Hz) |
Motor power kW |
Voltage V |
Weight kg |
Water vapor capacity g/Tag |
Air flushing L/min |
Inlet connection NW |
Outlet connection NW |
Cooling system |
Ambient temperature °C |
Back-up material | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
§ | m3/h | Single-phase | Three-phase | Single-phase | Three-phase | ||||||||||||
DVSL-501E | 430 | 28.8 | 100 | 1.0x100 | 0.9 | - | 200, 208, 230, 380, 400, 415, 460 | - | 36 | 250 (with air flushing) | 10 (with air flushing) | NW 25 (with Rc 1/2) | NW 25 (with outlet valve) | Air-cooled | 5~40 | Fluor rubber | |
DVSL-100C | 100 | 6.0 | 50 | 5.0 x 10-1 | 0.3 | 100, 115, 200, 230 | - | 15 | - | 100 (with air flushing) | 5 (with air flushing) | NW 25 (with Rc 3/8) | NW 16 (with outlet valve) | ||||
DVSL-500E | 430 | 25.8 | 30 | 3.0x10-1 | 0.9 | - | 200, 208, 230, 380, 400, 415, 460 | - | 36 | 250 (with air flushing) | 10 (with air flushing) | NW 25 (with Rc 1/2) | NW 25 (with outlet valve) | Air-cooled | 5~40 | silicone rubber | |
DVSL-1002E | 845 | 50.7 | 2.4 | 200,220 | 118 | 500 (with air flushing) | Air | Rc 1 | Air-cooled |